1.
Heart Lung Circ ; 28(7): 1050-1058, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31178023

RESUMO

BACKGROUND: A lower cut-off of the oesophageal temperature (ET) during catheter ablation of atrial fibrillation (AF) should be safer, but its durability may become in question. We evaluated an ET cut-off of 38°C with an output of 25W on the posterior wall. METHODS: In 636 consecutive patients (age: 60±10years, male: 542, paroxysmal AF: 405, CHADS2 score: 0.7±0.9), an ET probe was utilised in 303 patients (259 pulmonary vein isolations [PVIs] and 44 simultaneous isolations of the posterior wall and all PVs box isolations [BOXIs]). When the ET increased to >38°C, the radiofrequency delivery was switched off and the ablation point was tagged as an "EsoTag" by the CARTO™ system (Biosense Webster, Irvine, CA, USA). We analysed the characteristics of the ablation lesions at the EsoTags with respect to the dormant conduction, gaps in the redo-session, and ablation outcome. RESULTS: EsoTags were identified in 94.6% of the left PVIs and all BOXIs, and dormant conduction at the EsoTags was identified in 12.0% and 6.8%, respectively. In 10,796 ablation points, the ablation at the EsoTags that were associated with dormant conduction had a significantly shorter duration, smaller force-time integral, and smaller Δimpedance. The duration of an ET of >38°C was significantly and positively correlated with the body mass index and negatively with the left atrial appendage flow velocity. During the redo-sessions in a 10.5±6.0months of follow-up (PVI: 14.7%, BOXI: 11.4%), reconnections at the EsoTags with dormant conduction were observed only in two patients after the PVI. The AF survival rate did not significantly differ in the presence of dormant conduction at the EsoTags (83.1% vs. 75.0%, p=0.696). There were no patients hospitalised for gastroparesis. CONCLUSIONS: Atrial fibrillation ablation utilising an oesophageal temperature cut-off of 38°C might be safe and durable.


Assuntos
Fibrilação Atrial , Temperatura Corporal , Ablação por Cateter , Esôfago/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Am Heart Assoc ; 4(12)2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26627880

RESUMO

BACKGROUND: Although automated external defibrillators (AEDs) have contributed to a better survival of out-of-hospital cardiac arrests, there have been reports of their malfunctioning. We investigated the diagnostic accuracy of commercially available AEDs using surface ECGs of ventricular fibrillation (VF), ventricular tachycardia (VT), and supraventricular tachycardia (SVT). METHODS AND RESULTS: ECGs(VF 31, VT 48, SVT 97) were stored during electrophysiological studies and transmitted to 4 AEDs, the LifePak CR Plus (CR Plus), HeartStart FR3 (FR3), and CardioLife AED-2150 (CL2150) and -9231 (CL9231), through the pad electrode cables. For VF, the CL2150 and CL9231 advised shocks in all cases, and the CR Plus and FR3 advised shocks in all but one VF case. For VTs faster than 180 bpm, the ratios for advising shocks were 79%, 36%, 89%, and 96% for the CR Plus, FR3, CL2150, and CL9231, respectively. The FR3 and CR Plus did not advise shocks for narrow QRS SVTs, whereas the CL9231 tended to treat high-rate tachycardias faster than 180 bpm even with narrow QRS complexes. The characteristics of the shock advice for the FR3 differed from that for the CL9231 (kappa coefficient [κ]=0.479, P<0.001), and the CR Plus and CL2150 had characteristics somewhere between the 2 former AEDs (κ=0.818, P<0.001). CONCLUSIONS: Commercially available AEDs diagnosed VF almost always correctly. For VT and SVT diagnoses, a discrepancy was evident among the 4 investigated AEDs. The differences in the arrhythmia diagnosis algorithms for differentiating SVT from VT were thought to account for these differences.


Assuntos
Desfibriladores , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Desfibriladores/normas , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia